CHKACTOBJ       CHECK ACTIVE OBJECT                    TAAOBJK

 The  Check Active  Object  command  provides  a method  of  determining
 whether an object is in use.

 A typical command would be:

          CHKACTOBJ    OBJ(FILEX) OBJTYPE(*FILE)
          MONMSG       MSGID(CPF9898) EXEC(DO) /* In use */

 Only  object types  which can be  locked with  *EXCL can  be specified.
 The  typical  object  types  that are  excluded  are  described  in the
 OBJTYPE parameter  description.    Program object  types  are  rejected
 with  a message  that says  'Use the  CHKACTPGM' command.    You cannot
 specify  a device file (e.g.   Printer or Display  file) as they cannot
 be locked by ALCOBJ.

 The default  for the command  is to  use ALLOCATE(*TEST).   This  means
 that the object will  attempt to be allocated to a *EXCL  lock and then
 unlocked if successful.

 You  can also  specify *LOCK or  *UNLOCK.   Only *EXCL lock  states are
 requested.  If you need a different lock type, you must use ALCOBJ.

 Command parameters                                    *CMD
 ------------------

    OBJ           The qualified  object  to  be checked.    The  library
                  value defaults  to *LIBL.   *CURLIB may  be specified.

    OBJTYPE       The  object  type to  be  checked.    Only the  values
                  supported  by  ALCOBJ  that  support  *EXCL  locks are
                  valid.   This  excludes  such  object types  as  *CLS,
                  *CMD,  *DEVD,  *JOBD,   *JOBQ,  *JRN,  *JRNRCV,  *LIB,
                  *OUTQ,  and *TBL.  Because there  is a special command
                  used for  program objects,  *PGM  is rejected  with  a
                  message recommending the use of CHKACTPGM.

    ALLOCATE      The type of allocation.

                  *TEST is  the default and is  used to determine  if an
                  *EXCL  lock can  be achieved.   This performs  both an
                  allocate and deallocate function.   If the object  can
                  be locked,  it  is automatically  unlocked on  return.
                  A completion message is sent if successful.

                  The WAIT parameter on ALCOBJ is set to 2 seconds.

                  *LOCK  may be  specified  meaning to  attempt  to lock
                  the  object  with  an *EXCL  lock.   You  can  lock an
                  object more than once in  the same job.  Each  lock is
                  unique.   Therefore, if  you use CHKACTOBJ  with *LOCK
                  multiple  times in the same program,  you would have a
                  unique lock for  each use.   *UNLOCK may be  specified
                  to  unlock the  object.    The command  will  complete
                  normally  regardless of whether  a lock  had been held
                  or not (assuming it  is a valid  object).  The  system
                  does not send an  escape message if the object  is not
                  currently locked by the same job.

    MBR           The member  to be checked.   *DFT is the  default.  If
                  a  non-data base  file is  named, *DFT  means there is
                  no  member.   If  a  data  base file  is  named,  *DFT
                  becomes *FIRST or the first member of the file.

 Restrictions
 ------------

 None.

 Prerequisites
 -------------

 The following TAA Tools must be on your system:

          SNDCOMPMSG     Send completion message
          SNDESCMSG      Send escape message

 Implementation
 --------------

 None, the tool is ready to use.

 Objects used by the tool
 ------------------------

    Object        Type        Attribute      Src member    Src file
    ------        ----        ---------      ----------    ----------

    CHKACTOBJ     *CMD                       TAAOBJK       QATTCMD
    TAAOBJKC      *PGM           CLP         TAAOBJKC      QATTCL

Added to TAA Productivity Tools April 1, 1995


Home Page

Powered by AS/400Powered by AS/400 Last modified on January 12, 2010 © 1995, 2010 - Jim Sloan, Inc.