CPYBCKDTAQ      COPY BACK DATA QUEUE                   TAADTQO

 The Copy  Back Data  Queue command  is intended for  refreshing a  data
 queue or  duplicating the entries to a different  data queue.  You must
 first  convert the  entries in  the data queue  to the  DTAQP file with
 the TAA  CVTDTAQ command.   CPYBCKDTAQ  then  reads the  data from  the
 DTAQP file  and uses the  QSNDDTAQ API to  send the entries to  a named
 data queue.  Both keyed and non-keyed data queues are supported.

 Assume  you  have  used CVTDTAQ  to  convert the  entries  from  a data
 queue.  Now  you want  the same entries  in a different  data queue  or
 have  cleared the  original data  queue and  want to  copy the  entries
 back.

 A typical command would be:

             CPYBCKDTAQ     FILE(DTAQP) TODTAQ(xxx)

 The entries  would be read from the file and  the QSNDDTAQ API would be
 used to send them to the named data queue.

 There must be at least one record in the DTAQP file.

 The attributes of the  data queue that are  captured in the DTAQP  file
 must match those of the  DTAQ to send the entries to.   For example, if
 CVTDTAQ was  used for a keyed  data queue, you cannot  copy the entries
 back  to a  non-keyed data  queue.   The maximum  entry length  and the
 maximum key length must also agree.

 CPYBCKDTAQ escape messages you can monitor for
 ----------------------------------------------

       TAA9897    No records exist in DTAQP

 Escape messages from based on functions will be re-sent.

 Command parameters                                    *CMD
 ------------------

    FILE          The  qualified  name  of  the  DTAQP   file  that  was
                  created  by  the TAA  CVTDTAQ  command.   The  library
                  value  defaults to *LIBL.   *CURLIB may  also be used.

    TODTAQ        The qualified name  of the  DTAQ to  copy the  entries
                  to.   The library  value defaults  to *LIBL.   *CURLIB
                  may also be used.

                  The  attributes of  the data  queue that  are captured
                  in the  DTAQP file  must match  those of  the DTAQ  to
                  send the  entries to.   The  maximum entry length  and
                  the maximum key length must agree.

    MBR           The  member  of  the  DTAQP  file  to be  read.    The
                  default is DTAQP.

 Restrictions
 ------------

 See previous comments.

 CVTDTAQ is limited to a maximum entry length of 9,000.

 Prerequisites
 -------------

 The following TAA Tools must be on your system:

      CHKOBJ3         Check object 3
      EDTVAR          Edit variable
      RTVDTAQD        Retrieve data queue attributes
      SNDCOMPMSG      Send completion message
      SNDESCMSG       Send escape message
      SNDSTSMSG       Send status message

 Implementation
 --------------

 None, the tool is ready to use.

 Objects used by the tool
 ------------------------

    Object        Type    Attribute      Src member    Src file
    ------        ----    ---------      ----------    ----------

    CPYBCKDTAQ    *CMD                   TAADTQO       QATTCMD
    TAADTQOC      *PGM       CLP         TAADTQOC      QATTCL

Added to TAA Productivity Tools December 15, 2002


Home Page