MOVLIBOBJ       MOVE LIBRARY OBJECTS          TAALIBE

 The Move  Library  Objects command  moves some  or all  of the  objects
 from  one library to  another.   This is  useful for mass  migration of
 objects.

 The typical command would be:

       MOVLIBOBJ    FROMLIB(xxx) TOLIB(yyy)

 All  objects which can be moved would be.   Some object types like *JRN
 and *JRNRCV cannot be moved.   You must also be properly  authorized to
 move an object.

 At  the  completion  of  the  command, a  completion  message  is  sent
 describing  the number  of objects moved,  the number  bypassed and the
 number where failures (e.g.   not authorized)  occurred.  If an  object
 type or  generic name is  used, only  the objects meeting  the criteria
 are considered.

 Options exist on the command to move only:

   **   A specific object type (e.g.  *FILE).

   **   Generically named objects (An asterisk need not be specified)

   **   Objects  which start with  other than Q.   This can  be of value
        when moving user objects from QGPL.

 Combinations of criteria can  be specified such as  move all the  files
 beginning with ABC:

       MOVLIBOBJ    FROMLIB(xxx) TOLIB(yyy) OBJTYPE(*FILE) GENNAME(ABC)

 To move all  the objects from QGPL that  do not start with Q  you would
 specify:

       MOVLIBOBJ    FROMLIB(QGPL) TOLIB(yyy) EXCLUDE(*QNAMES)

 An option  also exists to  delete an existing  object of the  same name
 and type in the TOLIB library.

 Dependent logical files
 -----------------------

 If  a data base  network of physical  and logical files  is being moved
 to replace  an existing  network,  you must  specify DLTEXIST(*YES)  as
 with  any request  to move  an object  when the  TOLIB already  has the
 same object.

 If  DLTEXIST(*YES) is specified and  the object type is  *ALL or *FILE,
 a  separate  reading  of  the  outfile  occurs  to  first   delete  any
 corresponding logical  files before  attempting to  move the data  base
 network.

 This  allows  the network  to  be replaced  even  if  dependent logical
 files exist.

 Command parameters                                    *CMD
 ------------------

    FROMLIB       The library to move from.

    TOLIB         The library to move to.

    OBJTYPE       The object type to  move.  The default  is *ALL.   Any
                  object type  which can be  specified on MOVOBJ  can be
                  moved.

    GENNAME       A generic  name.  The  default is *NONE.   The generic
                  name should be entered without an *.

    EXCLUDE       Exclude  object.  The  default is *NONE.   *QNAMES can
                  be entered  to exclude  any objects  which begin  with
                  Q.

    DLTEXIST      Delete  existing object.    The default  is *NO  which
                  causes  a diagnostic message to occur  if an object of
                  the same name/type exists in the TOLIB library.

                  *YES may be  specified to use the  TAA tool DLTOBJ  if
                  the object already  exists in the TOLIB  library.  The
                  TAA  Tool DLTOBJ  only  deletes typical  object types.
                  If an object  type exists  which is  not processed  by
                  DLTOBJ,  the   object  will  not   be  moved   and  an
                  diagnostic message will be sent.

 Restrictions
 ------------

 None.

 Prerequisites
 -------------

 The following TAA Tools must be on your system:

       CHKGENERC     Check generic
       DLTOBJ        Delete object
       EDTVAR        Edit variable
       SNDCOMPMSG    Send completion message
       SNDESCMSG     Send escape message
       SNDSTSMSG     Send status message

 Implementation
 --------------

 None, the tool is ready to use.

 Objects used by the tool
 ------------------------

    Object        Type       Attribute      Src member     Src file
    ------        -----      ---------      ----------     -----------

    MOVLIBOBJ     *CMD                      TAALIBE        QATTCMD
    TAALIBEC      *PGM          CLP         TAALIBEC       QATTCL
    TAALIBEC2     *PGM          CLP         TAALIBEC2      QATTCL

Added to TAA Productivity Tools April 1, 1995